A kWh transducer which measures energy and power, and is placed in an electric service panel. The Wye-connection works with Magnelab AC Current Transformers and a Pulse Input Adapter to provide True RMS kilowatt hours of energy used, even for loads with non-sinusoidal waveforms. Used with U12 or UX120-series loggers.
Measurement Type: Energy
A kilowatt hour transducer with a Three split-core AC current sensors and three voltage leads and outputs a signal proportional to kilowatts of power (demand). Accepting an input primary voltage of 480 Volts AC rms, this transducer requires a Pulse Input Adapter.
Battery Charger for Web based data logger
A four-channel wireless data node with two analog ports and two pulse input ports. It wirelessly transmits data in real time using a mesh network of devices. Works with ZW-RCVR and ZW-Router.
A four-channel wireless data node that uses external sensors to measure data, rather than internal sensors built inside of the device. It supports temperature, AC current/voltage, air velocity, carbon dioxide, compressed air flow, DC current, DC voltage, gauge pressure, kilowatts, and volatile organic compound (VOC) measurements.
A four-channel wireless data node with four analog ports. It accepts external sensors and wirelessly transmits data in real time using a mesh network of devices. Works with ZW-RCVR and ZW-Router.
FlexSmart Analog Input Module for use with the H22-001 Energy Logger handles two single-ended input channels with user-configurable ranges of 0 to 20mA DC or 0 to 20 V DC which is suitable for 2.5-, 5-, and 10-volt sensors.
A dent power energy logger capable of analyzing electrical consumption data derived from voltage and current inputs. Uses direct connections to each phase of the voltage and various interchangeable CT options such as split-core current transformers.
A energy logger designed to be deployed with a variety of pre-defined plug-and-play smart sensors including: T-MAG-SCT-600, S-FS-CVIA, Tel 7001, T-WNB-3Y-208, S-LIB-M003, ADAPT-SER-USB.
A electronic switch pulse sensors with pulse outputs to data loggers with smart-sensor inputs. This Smart Sensor is compatible with electronic switch closures such as FET or open-collector outputs, or CMOS-level logic signals with a maximum input frequency of 120 Hz (120 pulses per second).