An air velocity sensor designed to measure airflow velocity. It functions as an adapter, providing greater flexibility in measurement. Compatible with UX120-006M or U12-006 loggers.
Application: Building Re-tuning
An AC current transformer with a measurement range of 7.5-75 amps AC. Designed to be mounted around a current-carrying wire, it provides a 0 to 0.333V AC output proportional to the current flow. Features a 0.40-inch window opening and is compatible with T-VER-E50B2 and H22-001 series loggers.
An AC power adapter that supplies DC power to sensors requiring external power. It expands the compatibility of third-party sensors with Onset’s HOBO RX3000, U12, U30-NRC, and ZW series products.
An AC current transformer with a measurement range of 60-600 amps AC. Designed to be mounted around a current-carrying wire, it provides a 0 to 0.333V AC output proportional to the current flow. Features a 2-inch window opening and is compatible with T-VER-E50B2 and H22-001 series loggers.
An AC current transformer with a measurement range of 60-600 amps AC. Designed to be mounted around a current-carrying wire, it provides a 0 to 0.333V AC output proportional to the current flow. Compatible with U12 and UX120-series loggers.
An AC current transformer with a responsive range of 5-50 amps AC. Designed to be mounted around a current-carrying wire to measure AC amperage, it provides a 0 to 0.333V AC output proportional to the current flow. Compatible with U12 and UX120-series loggers.
An AC current transformer with a responsive range of 5-50 amps AC. Designed to be mounted around a current-carrying wire to measure AC amperage, it provides a 0 to 0.333V AC output proportional to the current flow. Compatible with the H22-001 Energy Logger, Kwh Transducer and 4-Channel Pulse input logger.
A four-channel thermocouple data logger designed for measuring and recording temperature. It supports up to four J, K, T, E, R, S, B, or N type thermocouple probes. Requires HOBOware Pro or HOBOware free software for operation.
A four-channel data logger designed to record data from external sensors. It supports measurements for temperature, AC current, AC voltage, air velocity, carbon dioxide, compressed air flow, DC current, DC voltage, gauge pressure, power (watts), and volatile organic compounds (VOCs). Requires HOBOware Pro or HOBOware free software for operation.
A four-channel pulse logger primarily used with the T-VER-E50B2 energy meter, wiring kit, and current sensors. It measures and records pulse signals, events, state changes, and run times, with a pulse input range of 0-24VDC. Requires HOBOware Pro or HOBOware free software for operation.