Measurement and Verification Guides

As part of our partnership with the NYC DCAS Division of Energy Management (DEM), CUNY BPL has assembled several measurement guides for evaluating pre- and post-retrofit conditions of common retrofits associated with DEM-funded energy efficiency for agency use. Below are 10 of such guides that we have created for the following systems:

  1. AHU Fans
  2. Air-Cooled Chillers
  3. Boilers
  4. Secondary Chilled Water Pumps
  5. Cooling Tower Fans
  6. Demand Controlled Ventilation
  7. Lighting
    1. Dedicated panelboards with automatic controls
    2. Dedicated panelboards without automatic controls
    3. Mixed panelboards with automatic controls
    4. Mixed panelboards without automatic controls

Additionally, a single appendix document is available which describes step-by-step how to set up and deploy each measurement tool as well as more detailed calculation methodologies for each system. 

Each guide includes general information about the system (including key variables to measure), a guide for how to determine the measurement strategy and tools needed, general calculation methodology for determining annual energy consumption of the system, recommendations for best reporting practices, and a Beta version calculation tool that can be used to estimate annual consumption of the system.

The guides should be used to support the recommended measurement approach displayed in the measurement flowchart above. City agencies have access to customized coaching for collecting these measurements or using the calculation tools associated with each guide and system. The measurement process flowchart highlights steps where coaching may be most beneficial.

City Agencies are encouraged to reach out to BPL with any questions about these documents. To schedule a coaching session or discuss a project, please contact us at mvcoaching@cunybpl.org.

AHU Fans Measurement Guide

This guide describes the measurement approach for quantifying avoided energy use associated with retrofitting supply and return fans in air handling units with variable frequency drives and/or more efficient motors.

Download as PDF Related Kits Related Equipment

Calculation Workbooks

Air-Cooled Chiller Measurement Guide

This guide describes how to measure and analyze the annual energy consumption of an air-cooled chiller system as a complete replacement for an existing cooling tower and chiller.

Download as PDF Related Kits Related Equipment

Calculation Workbooks

Air Cooled Chillers Tool

Boiler Measurement Guide

This guide describes the measurement approach for quantifying avoided energy use associated with retrofitting existing boiler systems with more efficient boilers.

Download as PDF Related Kits Related Equipment

Calculation Workbooks

Boiler Tool

Secondary Chilled Water Pump Measurement Guide

This guide describes the measurement approach for quantifying avoided energy use associated with retrofitting pumps in the secondary loop of a chilled water pump system with variable frequency drives and/or more efficient motors.

Download as PDF Related Kits Related Equipment

Calculation Workbooks

Cooling Tower Fan Measurement Guide

This guide describes the measurement approach for quantifying avoided energy use associated with retrofitting evaporative cooling tower fans with variable frequency drives.

Download as PDF Related Kits Related Equipment

Calculation Workbooks

Demand Controlled Ventilation Measurement Guide

This guide describes the measurement approach for quantifying energy savings associated with an air handling unit system retrofitted with a demand control ventilation system.

Download as PDF Related Kits Related Equipment

Calculation Workbooks

Lighting Measurement Guide: Dedicated Panelboard with Automatic Controls

This guide describes the measurement approach for quantifying avoided energy use associated with retrofitting lighting systems with automatic controls, which are on panelboards that serve lighting loads only. The system may either have integrated control at the panelboard or distributed control, where controls replace manual wall switches in the occupied space and are frequently coupled with wireless occupancy sensors.

Download as PDF Related Kits Related Equipment

Calculation Workbooks

Lighting Measurement Guide: Dedicated Panelboard without Automatic Controls

This guide describes the measurement approach for quantifying avoided energy use associated with retrofitting lighting systems without automatic controls, which are circuited on panelboards that serve lighting loads only.

Download as PDF Related Kits Related Equipment

Calculation Workbooks

Lighting Measurement Guide: Mixed Panelboard with Automatic Controls

This guide describes the measurement approach for quantifying avoided energy use associated with retrofitting lighting systems with automatic controls, which are on panelboards that serve lighting loads other electrical loads (e.g., receptacles, equipment, etc.). The system may either have integrated control at the panelboard or distributed control, where controls replace manual wall switches in the occupied space and are frequently coupled with wireless occupancy sensors.

Download as PDF Related Kits Related Equipment

Calculation Workbooks

Lighting Measurement Guide: Mixed Panelboard without Automatic Controls

This guide describes the measurement approach for quantifying avoided energy use associated with retrofitting lighting systems without automatic controls, which are circuited on panels with other electrical loads (e.g., receptacles, equipment, etc.).

Download as PDF Related Kits Related Equipment

Calculation Workbooks