71 Items Available
Thermocouple Sensor (TC6-T)

A six-foot beaded thermocouple probe. This probe is Teflon-insulated and responsive over a range of -200 to 100℃ (-328 to 212℉) with an initial accuracy of +/- 1.5℃ (+/-2.7℉).

Temperature Sensor Boiler Chilled Water Loop
1 Items Available
Thermocouple Wire Type J (TC6-J)

Beaded Thermocouple probe includes 1.8m (6′) of insulated 30-AWG wire wound on an integrated spool caddy /subminiature connector. Color-coded for type J (black) thermocouples according to the ANSI standard.

Temperature Sensor Boiler Chilled Water Loop
0 Items Available
Power Quality Analyzer (Fluke 435 II )

Measures voltage, current, frequency, power, power consumption, unbalance, flicker, and harmonics in three- and single-phase power distribution systems.

Energy Operation Logger Boiler Chiller
2 Items Available
Power Quality Analyzer (Drantez Xplorer )

Capable of simultaneously capturing thousands of parameters, such as low-medium-high frequency transients through peak, waveshape, RMS difference, and adaptive high-speed sampling, as well as power measurements to clearly characterize harmonics, non-sinusoidal, and unbalanced systems.

Energy Operation Logger Boiler Chiller
17 Items Available
Power & Energy Meter (T-VER-E50B2)

A power management and energy efficiency meter that integrates with loggers such as the UX120-017, enabling you to measure power factor (PF), reactive power (VAR), watt hours (Wh), and more. Compatible with CTs from 5 to 32,000 A (333mV output) for current measurements.

Energy Operation Meter Boiler Chiller
1 Items Available
Power Demand Analyzer (DBEPFLEX6K-4 )

Provides advanced demand, energy, harmonics and power analysis, as well as display of phasors, scope mode, meters, harmonic spectrums, and sag/swell detection.

Energy Operation Logger Boiler Chiller
1 Items Available
Kilowatt Hour Transducer (T-VER-8053-800)

Three split-core AC current sensors and three voltage leads and outputs a signal proportional to kilowatts of power (demand). Accepting an input primary voltage of 480 Volts AC rms, this transducer requires a Pulse Input Adapter.

Energy Operation Meter Boiler Chiller
4 Items Available
Gauge Pressure Sensor (T-ASH-G2-500)

Provides precision pressure measurements in compressed air systems, water or other compatible gases and fluids with an accuracy of +/- 1% FS from -20°C to 85°C (-4°F to 185°F). Use with the UX120-006M or U12-006 loggers.

Pressure Sensor Chilled Water Loop Chiller
9 Items Available
Energy Logger (EXCUNC)

Capable of analyzing electrical consumption data derived from voltage and current inputs. Uses direct connections to each phase of the voltage and various interchangeable CT options such as split-core current transformers.

Energy Operation Logger Boiler Chiller