1 Items Available
Three Phase Electrical Energy Logger (Fluke 1730)

A three-phase electrical energy logger used for performing energy surveys and load studies. Measures voltage, current, power and power factor. Data can be downloaded from the logger onto a USB stick.

Energy Logger Boiler Chiller
75 Items Available
Thermocouple Sensor (TC6-T)

A six-foot beaded thermocouple probe. This probe is Teflon-insulated and responsive over a range of -200 to 100℃ (-328 to 212℉) with an initial accuracy of +/- 1.5℃ (+/-2.7℉). Ideal for measuring surface temperature.

Temperature Sensor Boiler Chilled Water Loop
1 Items Available
Thermocouple Wire Type J (TC6-J)

Beaded Thermocouple probe includes 1.8m (6′) of insulated 30-AWG wire wound on an integrated spool caddy /subminiature connector. Color-coded for type J (black) thermocouples according to the ANSI standard.

Temperature Sensor Boiler Chilled Water Loop
1 Items Available
Power Quality Analyzer (Fluke 435 II )

A power quality analyzer which measures voltage, current, frequency, power, power consumption, unbalance, flicker, and harmonics in three- and single-phase power distribution systems.

Energy Operation Logger Boiler Chiller
2 Items Available
Power Quality Analyzer (Drantez Xplorer )

A power quality analyzer that is capable of simultaneously capturing thousands of parameters, such as low-medium-high frequency transients through peak, waveshape, RMS difference, and adaptive high-speed sampling, as well as power measurements to clearly characterize harmonics, non-sinusoidal, and unbalanced systems.

Energy Operation Logger Boiler Chiller
20 Items Available
Power & Energy Meter (T-VER-E50B2)

A power management and energy efficiency meter that integrates with loggers such as the UX120-017, enabling you to measure power factor (PF), reactive power (VAR), watt hours (Wh), and more. Compatible with CTs from 5 to 32,000 A (333mV output) for current measurements.

Energy Operation Meter Boiler Chiller
1 Items Available
Power Demand Analyzer (DBEPFLEX6K-4 )

A power quality analyzer which provides advanced demand, energy, harmonics and power analysis, as well as display of phasors, scope mode, meters, harmonic spectrums, and sag/swell detection.

Energy Operation Logger Boiler Chiller
1 Items Available
Kilowatt Hour Transducer (T-VER-8053-800)

A kilowatt hour transducer with a Three split-core AC current sensors and three voltage leads and outputs a signal proportional to kilowatts of power (demand). Accepting an input primary voltage of 480 Volts AC rms, this transducer requires a Pulse Input Adapter.

Energy Operation Meter Boiler Chiller
4 Items Available
Gauge Pressure Sensor (T-ASH-G2-500)

A gauge pressure sensor which provides precision pressure measurements in compressed air systems, water or other compatible gases and fluids with an accuracy of +/- 1% FS from -20°C to 85°C (-4°F to 185°F) for up-to 500psi. Use with the UX120-006M or U12-006 loggers.

Pressure Sensor Chilled Water Loop Chiller
3 Items Available
Flex Smart Analog Module (S-FS-CVIA)

FlexSmart Analog Input Module for use with the H22-001 Energy Logger handles two single-ended input channels with user-configurable ranges of 0 to 20mA DC or 0 to 20 V DC which is suitable for 2.5-, 5-, and 10-volt sensors.

Energy Sensor Boiler Chiller