3 Items Available
Power Quality Clamp Meter (PQ2071)

Combines the functions of a clamp meter, oscilloscope, data logger and digital power meter in one device. Measures Power factor (PF), Reactive Power (VAR), Watt Hours (Wh), Kilowatt hours (kWh), AC Current, AC Voltage and more.

Energy Operation Meter Boiler Chiller
2 Items Available
Ultrasonic Leak Detector (UL101)

Used for condition monitoring and predictive maintenance. The UL101 is capable of accurately interpreting sounds created by under-lubrication, over-lubrication, and early signs of wear. Distance of reception is up to 150 ft (50 m) and threshold of sensitivity is 0 dB SPL.

Sound Meter Boiler Chiller
2 Items Available
Ultrasonic Flow Meter TFX (DTFXE-FC-AKEC-NA )

Clamp-on meter that can be fitted to the outside of pipes and does not contact internal liquid. No need to shut down processes for installation or maintenance. An ideal meter for water, wastewater, and chemical industry.

Temperature Water Flow Meter Chilled Water Loop Chiller
1 Items Available
Ultrasonic Flow Meter PT900 (PT900 )

Clamp-on flow meter that attaches fixture transducers onto the outside of a pipe to measure flow within the pipe without cutting into the pipe or shutting down the process. A useful spot measuring flow meter for applications such as wastewater, cooling and heating water, and other liquids.

Temperature Water Flow Meter Chilled Water Loop Chiller
3 Items Available
Ultrasonic Flow Meter DXNP (DXNP-ABS-NN )

Designed for systems engineers to quickly troubleshoot problems and verify performance during system commissioning and diagnostics. Allows measurement of flows throughout the plumbing infrastructure without intrusion.

Temperature Water Flow Meter Chilled Water Loop Chiller
1 Items Available
Three Phase Electrical Energy Logger (Fluke 1730)

Offers a three-phase electrical energy logger used for performing energy surveys and load studies. Measures voltage, current, power and power factor. Data can be downloaded from the logger onto a USB stick.

Energy Logger Boiler Chiller
1 Items Available
Thermocouple Wire Type J (TC6-J)

Beaded Thermocouple probe includes 1.8m (6′) of insulated 30-AWG wire wound on an integrated spool caddy /subminiature connector. Color-coded for type J (black) thermocouples according to the ANSI standard.

Temperature Sensor Boiler Chilled Water Loop
71 Items Available
Thermocouple Sensor (TC6-T)

A six-foot beaded thermocouple probe. This probe is Teflon-insulated and responsive over a range of -200 to 100℃ (-328 to 212℉) with an initial accuracy of +/- 1.5℃ (+/-2.7℉).

Temperature Sensor Boiler Chilled Water Loop