A mini 20 AMP split-core AC Current Transformer (CT) is mounted around a current carrying wire to measure AC amperage. This CT provides a 0 to .333 Volt AC output proportional to current flow and is used with onset data loggers such as the (T-VER-E50B2) Power & Energy meter that integrates with loggers such as… Continue reading 2-20 Amp mini Split-Core (T-MAG-0400-20)
Equipment Library
The core of our mission is to get the right tools for the job into your hands. Search the catalogue by equipment type, measurement type, or building system, and add items to your cart to borrow free of cost. If we don’t have what you’re looking for, let us know what you’d like to see in the catalog.
Capable of simultaneously capturing thousands of parameters, such as low-medium-high frequency transients through peak, waveshape, RMS difference, and adaptive high-speed sampling, as well as power measurements to clearly characterize harmonics, non-sinusoidal, and unbalanced systems.
Measures voltage, current, frequency, power, power consumption, unbalance, flicker, and harmonics in three- and single-phase power distribution systems.
Provides advanced demand, energy, harmonics and power analysis, as well as display of phasors, scope mode, meters, harmonic spectrums, and sag/swell detection.
A power management and energy efficiency meter that integrates with loggers such as the UX120-017, enabling you to measure power factor (PF), reactive power (VAR), watt hours (Wh), and more. Compatible with CTs from 5 to 32,000 A (333mV output) for current measurements.
Three split-core AC current sensors and three voltage leads and outputs a signal proportional to kilowatts of power (demand). Accepting an input primary voltage of 480 Volts AC rms, this transducer requires a Pulse Input Adapter.
Capable of analyzing electrical consumption data derived from voltage and current inputs. Uses direct connections to each phase of the voltage and various interchangeable CT options such as split-core current transformers.
Responsive over the range of 7.5-75 amps AC. Mounted around a current carrying wire to measure AC amperage. Provides a 0 to .333 V AC output proportional to current flow. Window opening of 0.40 inch. Used with T-VER-E50B2, H22-001 series loggers.
Responsive over the range of 60-600 amps AC. Mounted around a current carrying wire to measure AC amperage. Provides a 0 to .333 V AC output proportional to current flow. Used with U12 or UX120-series loggers.
Responsive over the range of 60-600 amps AC. Mounted around a current carrying wire to measure AC amperage. Provides a 0 to .333 V AC output proportional to current flow. Window opening of 2 inches. Used with T-VER-E50B2, H22-001 series loggers.